Shipping to:Chico, CA
Kohler Power Systems RCA Series 14kW (120 / 240V) Single-Phase Air Cooled Multi-Fuel Standby Generator with RXT 200a Automatic Transfer Switch
Model: 14RCAL-200SELS|Item: bci5167898
from theRCA Series Collection
Details
Features:
- 14kW (LPG) / 12kW (NG) Air-Cooled Standby Generator: Protects your home and family during a power outage
- Fully Automatic Operation - Includes Automatic Transfer Switch
- RXT 200A Service Entrance Rated Outdoor Automatic Transfer Switch
- NEMA 3R Enclosure mounts between meter and main service panel
- Built-In Load Shed - Manage (2) HVAC + (4) Non-Essential loads***
- Kohler Command PRO OHV Engine
- Meets emission regulations for U.S. EPA and California
- Powerful and reliable engine with hydraulic valve lifters
- New 100% Corrosion-Proof Aluminum Enclosure
- Aluminum base can be mounted on gravel or cement pad
- Meets 181 MPH wind rating Impact-resistant down to -30° F
- Powerful Performance with PowerBoost Technology: Greater motor-starting ability for large electrical loads
- Premium Power Quality (+/-1% Voltage Regulation): Protects sophisticated electronics with low distortion (<5%THD)
- Fast Response Time: Kohler generators restore power in as little as 10 seconds
- New Silencer Reduces Sound Levels and Provides Quiet Operation: Maintains neighborhood solitude - approx. 67 dB(A) at 7 m (23 ft)
- RDC2 Digital Controller
- Glare-resistant, 2-line 16-character display - No More Codes
- ATS status via LED lights on controller Built-In 2.5A Battery Charger
- Real time clock allows you to easily set weekly exercise
- Remote Monitoring System (Included)
- Built-in Ethernet card, no hardware needed
- Requires OnCue Plus Wireless Radio Kit For Wireless Monitoring (Sold Separately)
- Kohler Energy Management App: Get real-time alerts on generator status, remote control and maintenance records
- Easier Installation: Streamline design reduces time required to install generator
- Installation Flexibility*
- Can be installed within 18" of a building / home
- *Always check local building codes
- Premium Warranty - 5-Year / 2,000-Hour Limited Warranty
- ***Requires PRM (Sold Separately)
Manufacturer Resources
Accessories BrochureEnergy Management SheetInstallation DrawingInstallation SheetOwners ManualProduct LiteratureWarrantyLoad Shed SpecificationsSpecification SheetTransfer Switch Specifications: RXTDimensions and Measurements
Height | 32.2 in. |
Length | 47 in. |
Product Weight | 440 lbs. |
Width | 26.2 in. |
Dimensions and Measurements
Height | 32.2 in. |
Length | 47 in. |
Product Weight | 440 lbs. |
Width | 26.2 in. |
Included Components
Automatic Transfer Switch Included | Yes |
Included Components
Automatic Transfer Switch Included | Yes |
Characteristics and Features
ATS Features | Built-In Load Prioritizing, Built-In Load Shedding, Integrated Service Disconnect |
Cooling Type | Air Cooled |
Enclosure Material | Aluminum |
Engine Brand | Kohler |
Generator Features | Low Oil Alert/Shutdown |
Characteristics and Features
ATS Features | Built-In Load Prioritizing, Built-In Load Shedding, Integrated Service Disconnect |
Cooling Type | Air Cooled |
Enclosure Material | Aluminum |
Engine Brand | Kohler |
Generator Features | Low Oil Alert/Shutdown |
Electrical and Operational Information
Air Conditioner Ton Rating | (2) 5-Tons |
Alternator | Brushed |
Amperage | 58 |
Cubic Capacity | 725 cc |
Decibel Rating @ 7m | 62 |
Electrical Phases | 1 |
Frequency | 60 Hertz |
Fuel Type | Liquid Propane, Natural Gas |
Horsepower | 20.5, 23.6 |
LP Fuel Consumption @ 100% Load | 2.3 GPH |
LP Fuel Consumption @ 50% Load | 1.8 GPH |
LP Power Capacity | 14000 |
NG Fuel Consumption @ 100% Load | 193 CFH |
NG Fuel Consumption @ 50% Load | 124 CFH |
NG Power Capacity | 12000 |
RPM | 3600 |
Running Wattage | 14000 |
Starting System | 12v Auto Start |
Transfer Switch Amperage | 200 |
Transfer Switch Style | Service Disconnect |
Voltage | 120, 240 |
Electrical and Operational Information
Air Conditioner Ton Rating | (2) 5-Tons |
Alternator | Brushed |
Amperage | 58 |
Cubic Capacity | 725 cc |
Decibel Rating @ 7m | 62 |
Electrical Phases | 1 |
Frequency | 60 Hertz |
Fuel Type | Liquid Propane, Natural Gas |
Horsepower | 20.5, 23.6 |
LP Fuel Consumption @ 100% Load | 2.3 GPH |
LP Fuel Consumption @ 50% Load | 1.8 GPH |
LP Power Capacity | 14000 |
NG Fuel Consumption @ 100% Load | 193 CFH |
NG Fuel Consumption @ 50% Load | 124 CFH |
NG Power Capacity | 12000 |
RPM | 3600 |
Running Wattage | 14000 |
Starting System | 12v Auto Start |
Transfer Switch Amperage | 200 |
Transfer Switch Style | Service Disconnect |
Voltage | 120, 240 |
Warranty and Product Information
Approved for Commercial Use | Yes |
CARB approved | Yes |
Certifications | UL |
EPA Compliant | Yes |
Made in America | Yes |
Manufacturer Warranty | 5 Year |
SCAQMD Compliant | No |
Warranty and Product Information
Approved for Commercial Use | Yes |
CARB approved | Yes |
Certifications | UL |
EPA Compliant | Yes |
Made in America | Yes |
Manufacturer Warranty | 5 Year |
SCAQMD Compliant | No |
Related Kohler Power Systems Categories