Shipping to:Chico, CA
Kohler Power Systems RDT 200-Amp 120 / 240V Single-Phase Service Disconnect Automatic Transfer Switch
Model: RDT-CFNC-200BSEQS3|Item: bci5215518
Details
Features:
- Kohler RDT Series 200-Amp Automatic Transfer Switch
- Compatible with all Kohler 120/240V 1-phase generators
- Service Entrance Rated
- Includes disconnect circuit breakers on both gen/utility sources
- 42 Circuit Load Center (Breakers Not Included)
- Easily add a gen to buildings with previously installed electrical
- Gray Aluminum Indoor/Outdoor (NEMA 3R) Cabinet
- Corrosion-resistant design is also Lockable for added security
- MPACâ„¢ 500 Controller
- User-friendly interface and easy-to-find international symbols
- Selectable source for easy contractor servicing
- LED Fault Indicators
- Failure to acquire standby source, failure to transfer and Aux. faults
- Test and Exercise Button
- Allows for both of these options with or without a load
- Double Throw, Inherently Interlocked Design
- Contactor electrically and mechanically interlocked
- Rated at 200-Amps @ 240-Volts
- Please See Spec Sheet For Technical Information
- 5-Year Limited Warranty - UL Listed
Overview:
- Transfer Switch Style: Service Disconnect
- Product Weight: 70 lbs
- Depth: 6-3/8"
- Width: 18-5/8"
- Height: 33-13/16"
Specifications:
- Voltage: 120, 240V
- Frequency: 60 Hz
- Electrical Phases: 1
- Max Generator Input: 200A
- Max Utility Input: 200A
- Enclosure Material: NEMA 3R
Product Assurance:
- Certifications: UL
- Warranty: 5 Year
Dimensions and Measurements
Depth | 6.4 in. |
Height | 33.8 in. |
Product Weight | 70 lbs. |
Width | 18.6 in. |
Dimensions and Measurements
Depth | 6.4 in. |
Height | 33.8 in. |
Product Weight | 70 lbs. |
Width | 18.6 in. |
Characteristics and Features
Enclosure Material | NEMA 3R |
Characteristics and Features
Enclosure Material | NEMA 3R |
Electrical and Operational Information
Amperage | 200 |
Electrical Phases | 1 |
Frequency | 60 Hertz |
Max Generator Input | 200 |
Max Utility Input | 200 |
Running Wattage | 48000 |
Transfer Switch Style | Service Disconnect |
Voltage | 120, 240 |
Electrical and Operational Information
Amperage | 200 |
Electrical Phases | 1 |
Frequency | 60 Hertz |
Max Generator Input | 200 |
Max Utility Input | 200 |
Running Wattage | 48000 |
Transfer Switch Style | Service Disconnect |
Voltage | 120, 240 |
Warranty and Product Information
Certifications | UL |
Manufacturer Warranty | 5 Year |
Warranty and Product Information
Certifications | UL |
Manufacturer Warranty | 5 Year |
Related Kohler Power Systems Categories
Reviews
(0)