Goodman GM9C80 Series 120,000 BTU Two Stage Natural Gas Furnace - 80% AFUE
Model: GM9C801205DN|Item: bci4746034
Details
Goodman's GM9C80 two-stage, multi-speed furnace was designed to provide premium efficiency at an affordable price. The GM9C80 utilizes Goodman's superior heat exchanger design to provide efficient, reliable heating and ensure that your energy dollars aren't being vented out of your home. Instead of a standard multi-speed blower motor, the GM9C80 utilizes an ECM motor, which uses less power and provides smarter circulation. The value doesn't end at efficiency, the GM9C80 features many different connection options to reduce installation time and a self-diagnosing control board to expedite maintenance. If you're looking to cut your energy bills and improve your comfort without breaking the bank, your search stops with the GM9C80.
Features:
- Advanced Heat Exchanger Design
- The GM9C80 furnace employs a reliable tubular heat exchanger design. Aluminized steel is used in construction for incredibly efficient heat transfer and wrinkle-bend technology for extraordinary durability. Multi-Speed ECM Motor
- The GM9C80's energy efficient blower motor uses the lowest speed it can to deliver precise temperature control for your home while keeping utility bills to a minimum. Quiet Comfort
- Goodman takes great pride in producing equipment that doesn't disrupt your home. The blower and gas valve of the GM9C80 were selected for their incredibly low sound levels. Secure Cabinet
- All GM9C80 furnaces are protected by a durable steel cabinet rated for less than 2% air leakage. The heat exchanger section is insulated to prevent heat loss and the return side of the cabinet is solid and airtight. Self-Diagnostic Control Board
- The GM9C80 continuously monitors the system to ensure reliable operation, stores the last diagnostic codes in memory, and a flashing LED indicates condition for quick troubleshooting. Extended Warranty
- Goodman offers a 10-year limited unit replacement and parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See the "Manuals" tab for more information.
General Information:
- Fuel Type: Natural Gas
- Heater Type: Furnace
- Vent Type: Chimney
- Stage: Two Stage
- Blower Motor Type: Electronically Commutated Motor (ECM)
- Airflow Orientation: Horizontal, Upflow
Performance:
- AFUE Rating 80%
- Heating BTU: 120,000
- High Fire Input: 120,000
- High Fire Output: 96,000
- NOx Emissions: Standard
Electrical Data:
- Voltage: 115V
- Electrical Phases: 1
- Frequency: 60 Hz
- Breaker Needs: 20 Amps
Dimensions:
- Height: 33-3/8"
- Width: 24-1/2"
- Depth: 28"
- Weight: 124 lbs
Product Assurance:
- Certifications:
- AHRI
- ETL
- ISO
- AHRI Reference Number: 207254765
- Manufacturer Warranty: 10 Year Parts, Limited Lifetime Heat Exchanger
Dimensions and Measurements
Cabinet Width | 24.5 in. |
CFM | 2000 |
Depth | 28 in. |
Height | 33.375 in. |
Nominal Depth | 28 in. |
Nominal Height | 34 in. |
Nominal Width | 25 in. |
Product Weight | 124 lbs. |
Width | 24.5 in. |
Dimensions and Measurements
Cabinet Width | 24.5 in. |
CFM | 2000 |
Depth | 28 in. |
Height | 33.375 in. |
Nominal Depth | 28 in. |
Nominal Height | 34 in. |
Nominal Width | 25 in. |
Product Weight | 124 lbs. |
Width | 24.5 in. |
Included Components
Vent Free | No |
Included Components
Vent Free | No |
Characteristics and Features
Airflow Orientation | Horizontal, Upflow |
Heater Type | Furnace |
Motor Type | Electronically Commutated Motor (ECM) |
NG Conversion | Yes |
Vent Type | Chimney |
Characteristics and Features
Airflow Orientation | Horizontal, Upflow |
Heater Type | Furnace |
Motor Type | Electronically Commutated Motor (ECM) |
NG Conversion | Yes |
Vent Type | Chimney |
Electrical and Operational Information
Amperage | 15.32 |
Breaker Needs | 20 Amps |
BTU Heating | 120000 |
Electrical Phases | 1 |
Frequency | 60 Hertz |
Fuel Type | Natural Gas |
High Fire Input | 120000 |
High Fire Output | 96000 |
Low Fire Input | 84000 |
Low Fire Output | 67200 |
Stages | Two Stage |
Voltage | 115 |
Electrical and Operational Information
Amperage | 15.32 |
Breaker Needs | 20 Amps |
BTU Heating | 120000 |
Electrical Phases | 1 |
Frequency | 60 Hertz |
Fuel Type | Natural Gas |
High Fire Input | 120000 |
High Fire Output | 96000 |
Low Fire Input | 84000 |
Low Fire Output | 67200 |
Stages | Two Stage |
Voltage | 115 |
Warranty and Product Information
AFUE Rating | 80 % |
AHRI Reference Number | 207254765 |
Certifications | AHRI, ETL, ISO |
Collection | GM9C80 |
DOE Regional Compliance | Nationwide |
Energy Star | Yes |
Manufacturer Warranty | 10 Year Parts, Limited Lifetime Heat Exchanger |
NOx Emissions | Standard |
Warranty and Product Information
AFUE Rating | 80 % |
AHRI Reference Number | 207254765 |
Certifications | AHRI, ETL, ISO |
Collection | GM9C80 |
DOE Regional Compliance | Nationwide |
Energy Star | Yes |
Manufacturer Warranty | 10 Year Parts, Limited Lifetime Heat Exchanger |
NOx Emissions | Standard |